Datalogger Issues Mapfeat 3286 Error(SprtNote_AssSurv_Mapfeat3286.pdf - 119 KB)With Asset Surveyor version 5.25, if you turn off the TSC1 data collector when a background map is open in the Map window, the data collector displays the error message Mapfeat 3286 the next time you turn it on. This document identifies how to correct this error.
What to Do If You End Up in the Operating System Menu on Your MC-V Datalogger(mcvopsys.pdf - 30 KB)When the batteries in your MC-V datalogger go flat, or when you exit the datalogging software, you end up on an operating system page. In this situation, you need to check whether the datalogging software is still on your MC-V datalogger, and if it's not, you need to reload the software. This TIP includes instructions for checking whether the software is on your datalogger and, if not, for reconfiguring.
What to Do if Your MC-V Gets Stuck in an Endless Loop When You Are Running Asset Surveyor(mc5stop.pdf - 18 KB)Sometimes your Corvallis MicroTechnology MC-V will fail on program execution while you are running Asset Surveyor?, and it will get stuck in an endless loop. There are two ways to stop the program: (1) rebooting the MC-V while bypassing the AUTOEXEC.S file and (2) stopping the program that's running. Once you have restarted your MC-V, you can solve the problem that caused your MC-V to get stuck. This TIP includes instructions for stopping the program and for solving the problem that caused it to get stuck.
Resolving Fatal Errors: Module Heap and Error Code 0 on MC-V Asset Surveyor Software(modheap.pdf - 11 KB)MC-V Asset Surveyor version 3.16 may exhibit fatal errors Module Heap and Error Code 0 which indicate corrupted communication files. Fixing faulty cabling or a hard reset should resolve the problem. This TIP gives the procedure to eliminate these fatal errors.
Getting Out of the MCV Autoexec Loop(mcvload.pdf - 11 KB)When the I drive becomes corrupted, the MCV gets stuck in the Autoexec loop. This TIP describes how to get out of the loop.
How to Get Out of the Autoexec Loop After You Boot Up Your TDC2 Datalogger(tdc2loop.pdf - 10 KB)When you turn on your TDC2 datalogger, you will be in the Autoexec loop. This TIP includes instructions for getting out of the loop.
How to Recover a GPS Pathfinder Pro XL TDC2 That Has Become Locked-Up(tdc2rcov.pdf - 17 KB)The GPS Pathfinder Pro XL™ TDC2 may become locked-up or unresponsive under certain circumstances. For example, a lock-up could occur during a firmware upgrade if the cable gets disconnected. This TIP provides the instructions for recovering a TDC2 that has become locked-up.
What Your Two Options Are for Replacing MC-V Batteries and How to Proceed(battprc.pdf - 8 KB)If you need to replace your MC-V batteries, you have two options: (1) you may send in the MC-V to Trimble Navigation Ltd. and we will replace them, or (2) you may purchase the batteries and replace them yourself. This TIP includes instructions and prices for these two options.
Correct Use of the TSC1? Data Cable(TIP_TSC1_connector_using.pdf - 26 KB)The TSC1 data cable (PN 32287-00) is designed to provide a reliable connection between the TSC1 data collector and the GPS receiver. However, the cable may be prone to damage if
incorrectly removed from the TSC1. This document outlines the correct procedure to remove this cable.
|